MITSUBISHI/SME Diesel Generator






Product Information:
Â
Genset Model | J1250MS |
Rated Power | 1000/1250 (KW/KVA) |
Standby Power | 1100/1375 (KW/KVA) |
Frequency | 50HZ |
Technical Indication:
With rigid connection,the small and medium-sized genset equipped with integrated base fuel tank, stainless steel efficient absorber.There is no specail request for the genset installation.The genset can realize full load output at an altitude of 1000 meters and the ambient temperature below 40 ºC.In other circumstance, the genset can in accordance with the relevant standard to output power.
Standard Configuration:
Engine: SME S12R-PTA-C
Â
Alternator:Single-bearing ,IP23 Protection level
Â
Radiator: 40 ºC Radiator Water Tank
Â
Control Panel: Auto-start,Auto-protect LCD ScreenÂ
Â
Breaker: Standard Three-pole Air SwitchÂ
Â
Accumulator:12V Maintenance-free Battery 2 pcs
Â
Absorber:Stainless Steel High-efficiency Absorber
Â
Common Base: Steel Plate Base Plate
Â
Auxiliary:Exhaust Bellows,Exhaust Bended Pipe, Industrial muffler and a set of attachment tool
Different Voltage Grade Genset:
Â
Voltage (V) |
Frequency (HZ) |
Phase | Power Factor (COSΦ) |
Standby Current (A) |
Standby Power (KW/KVA) |
Rated Power (KW/KVA) |
254/440 | 50 | 3 | 0.8 | 1804Â | 1100/1375 | 1000/1250 |
240/415 | 50 | 3 | 0.8 | 1913Â | 1100/1375 | 1000/1250 |
230/400 | 50 | 3 | 0.8 | 1985Â | 1100/1375 | 1000/1250 |
220/380 | 50 | 3 | 0.8 | 2089Â | 1100/1375 | 1000/1250 |
Rated Power:In accordance with GB/T2820-97(eqvISO8528),There is no limitation to the annual hours of operation and this model can supply 10% over-load power for 1 hour in 12 hours.
Â
Standby Power:There ratings are applicable for supplying continuous electrical power in the event of a utility power failure.
Genset Parameter:
Voltage range:±5%
Voltageregulation:≤±1%Â
Â
Frequencyregulation:≤5%
Â
Frequency fluctuation rate:≤1.5%
Â
Transient frequency deviation sudden increase: ≤--10%Â
Â
Frequency recovery time sudden increase: ≤5S
Â
Voltage stability time 100%sudden reduce:≤6SÂ
Â
Frequency recovery time100%sudden reduce: ≤5SÂ
Â
Transient frequency deviation 100%sudden reduce: ≤+12%Â
Â
Transient voltage deviation100%sudden reduce: ≤+25%
Â
Transient voltage deviation sudden increase: ≤--20%
Â
 Voltage stability time sudden increase: ≤6S
Engine Parameter:
Brand/Origin:SME/China
Â
Cylinders:12vertical in-line
Â
Governor Type:Electronic
Â
Start method:DC24VElectric start
Â
Model:S12R-PTA-C
Â
Bore x Stroke:170*180(mm)
Â
Cooling Method:Closed circulated water-coolingÂ
Â
Air intake Method:Turbocharged
Â
Max Power:1190KW
Â
Rated Speed:1500rpm
Â
Type of injection:Direct injectionÂ
Alternator Parameter :
Brand/Model: Stamford/LV1634G
Â
Phase:Three phase
Â
Bearing number:1Â
Â
Exciter type:Brushless, self-exciting
Â
Protect Grade:IP22Â
Â
Power Factor:COSΦ=0.(lagging)
Â
Insulation Grade:H Â Â
   Â
Adjusting mode:AVR
Â
Telephone  influence factor THF:<50Â
Â
Connection:Three phase four wire, Y connection
Options:
Engine: Water-jacket heater,Battery Charge,50ºCradiator water tank,oil-water separatorÂ
Â
Alternator: Anti-condensation heater,Permanent magnet generator
Â
Genset:Silent Type,Super Silent Type,Trailer Type,Container Type,Anti-rain Type
Â
Others:Base fuel tank,Daily fuel tank,Automatic adding fuel system
Â
Electrical Options:Luxurious Auto Control Panel,ATS Auto over-load Control Panel,Auto Parallel Operation Control Panel,Power output cabinetÂ
Â
Our Services:
1.Before sale Service: we provide detailed product technical parameters for equipment choosing and system designing.
2.Onsale Service: 24 hours online support technical guidance, remote installment, maintenance ,technique instruction.
3.After-sale maintenance service:We create files for users and provide them follow-up service,regular return visit and permanent maintenance.
4.Spare parts supply:We provide all kinds of spare parts and technical support.
5.Service quality assurance:our sale staffs are all experience and professional,who can provide the most proper system design and optimized equipment for the customers.
MITSUBISHI/SME Diesel Generator






Product Information:
Â
Genset Model | J1250MS |
Rated Power | 1000/1250 (KW/KVA) |
Standby Power | 1100/1375 (KW/KVA) |
Frequency | 50HZ |
Technical Indication:
With rigid connection,the small and medium-sized genset equipped with integrated base fuel tank, stainless steel efficient absorber.There is no specail request for the genset installation.The genset can realize full load output at an altitude of 1000 meters and the ambient temperature below 40 ºC.In other circumstance, the genset can in accordance with the relevant standard to output power.
Standard Configuration:
Engine: SME S12R-PTA-C
Â
Alternator:Single-bearing ,IP23 Protection level
Â
Radiator: 40 ºC Radiator Water Tank
Â
Control Panel: Auto-start,Auto-protect LCD ScreenÂ
Â
Breaker: Standard Three-pole Air SwitchÂ
Â
Accumulator:12V Maintenance-free Battery 2 pcs
Â
Absorber:Stainless Steel High-efficiency Absorber
Â
Common Base: Steel Plate Base Plate
Â
Auxiliary:Exhaust Bellows,Exhaust Bended Pipe, Industrial muffler and a set of attachment tool
Different Voltage Grade Genset:
Â
Voltage (V) |
Frequency (HZ) |
Phase | Power Factor (COSΦ) |
Standby Current (A) |
Standby Power (KW/KVA) |
Rated Power (KW/KVA) |
254/440 | 50 | 3 | 0.8 | 1804Â | 1100/1375 | 1000/1250 |
240/415 | 50 | 3 | 0.8 | 1913Â | 1100/1375 | 1000/1250 |
230/400 | 50 | 3 | 0.8 | 1985Â | 1100/1375 | 1000/1250 |
220/380 | 50 | 3 | 0.8 | 2089Â | 1100/1375 | 1000/1250 |
Rated Power:In accordance with GB/T2820-97(eqvISO8528),There is no limitation to the annual hours of operation and this model can supply 10% over-load power for 1 hour in 12 hours.
Â
Standby Power:There ratings are applicable for supplying continuous electrical power in the event of a utility power failure.
Genset Parameter:
Voltage range:±5%
Voltageregulation:≤±1%Â
Â
Frequencyregulation:≤5%
Â
Frequency fluctuation rate:≤1.5%
Â
Transient frequency deviation sudden increase: ≤--10%Â
Â
Frequency recovery time sudden increase: ≤5S
Â
Voltage stability time 100%sudden reduce:≤6SÂ
Â
Frequency recovery time100%sudden reduce: ≤5SÂ
Â
Transient frequency deviation 100%sudden reduce: ≤+12%Â
Â
Transient voltage deviation100%sudden reduce: ≤+25%
Â
Transient voltage deviation sudden increase: ≤--20%
Â
 Voltage stability time sudden increase: ≤6S
Engine Parameter:
Brand/Origin:SME/China
Â
Cylinders:12vertical in-line
Â
Governor Type:Electronic
Â
Start method:DC24VElectric start
Â
Model:S12R-PTA-C
Â
Bore x Stroke:170*180(mm)
Â
Cooling Method:Closed circulated water-coolingÂ
Â
Air intake Method:Turbocharged
Â
Max Power:1190KW
Â
Rated Speed:1500rpm
Â
Type of injection:Direct injectionÂ
Alternator Parameter :
Brand/Model: Stamford/LV1634G
Â
Phase:Three phase
Â
Bearing number:1Â
Â
Exciter type:Brushless, self-exciting
Â
Protect Grade:IP22Â
Â
Power Factor:COSΦ=0.(lagging)
Â
Insulation Grade:H Â Â
   Â
Adjusting mode:AVR
Â
Telephone  influence factor THF:<50Â
Â
Connection:Three phase four wire, Y connection
Options:
Engine: Water-jacket heater,Battery Charge,50ºCradiator water tank,oil-water separatorÂ
Â
Alternator: Anti-condensation heater,Permanent magnet generator
Â
Genset:Silent Type,Super Silent Type,Trailer Type,Container Type,Anti-rain Type
Â
Others:Base fuel tank,Daily fuel tank,Automatic adding fuel system
Â
Electrical Options:Luxurious Auto Control Panel,ATS Auto over-load Control Panel,Auto Parallel Operation Control Panel,Power output cabinetÂ
Â
Our Services:
1.Before sale Service: we provide detailed product technical parameters for equipment choosing and system designing.
2.Onsale Service: 24 hours online support technical guidance, remote installment, maintenance ,technique instruction.
3.After-sale maintenance service:We create files for users and provide them follow-up service,regular return visit and permanent maintenance.
4.Spare parts supply:We provide all kinds of spare parts and technical support.
5.Service quality assurance:our sale staffs are all experience and professional,who can provide the most proper system design and optimized equipment for the customers.
Mainly used for drilling water wells, monitoring wells, geothermal air condition ing hole construction, national defense projects,anti-floating anchor rod,cable anchor rod,high-pressure Rotary Jet Drilling Operations;At the same time, it is suitable for large diameter vertical hole construction in geotechnical engineer- ing such as hydropower station,railway,highway and city foundation, grouting reinforcement hole, small foundation pile holemicro-pile etc..
Construction Features:
1.The power head of drilling rig can change speed both mechanically and hydraulically. Suitable for down-hole Hammer,eel pipe, full casing and alloy rotary drilling methods.
2.Two large cylinders on the mast, lifting force up to 25 tons, eccentric with pipe drilling can be used to pull out casing,but also for small-scale non-excavation construction.
3.The rig uses inside and outside telescopic mast power head travel up to 7 meters, can drill 23 meters drill pipe at a time, reduce a time to add drill pipe, improve efficiency twice.
Hydraulic Drilling Rig,Hydraulic Rig Machine,Hydraulic Piling Machine,Hydraulic Drilling Machine
JIANGSU XI TEC ENVIRONMENTAL&DRILLING EQUIPMENT COMPANY CO.LTD , https://www.xitecdrillingwx.com