ZX series of horizontal self-priming pump is characterized by simple structure, reliable, durable. In the normal case of the pump, generally do not often need to dismantle the staff Q? 5 embarrassingly stop shrimp watt equipment? Cowardly? Pure umbrella?
1. Maintain the pump should pay attention to several major parts:
a. Rolling bearings: when the pump is running for a long time, bearing wear to a certain extent, to be replaced.
b. Front seal ring, rear seal ring: When the seal ring wear to a certain extent, to be replaced.
c. mechanical seal: mechanical seal in the case of liquid leakage, the general should not be demolished 约 椤 ç³ H ç³ å²¢ 逑 逑 逑 逑 statement solitary â”› 诖 Σ ??èƒ é¸º è‡ W security å¾— W security å¾— 芊 芊 é¦??? 匦 raised? â’ Hamamatsu Hamamoto that 褰 啵 ãš ãš;å¤ èˆ› ??? Solitary brain 蛑 gluttonous? Σ Σ food poisoning 胬 diarrhea F 湫 è–· window æ—† ÇŽ? What read GS grain shake prostitutes? Awakening ナ enough refers to Chun was 妗;å¤ å¤ animal husbandry 硪 Hui? èš´? Precisely the right? "Rubber seals (or cushion) improper installation, or deformation aging to this time you need to adjust or replace the" O "ring for reassembly.
2. Self-priming pump disassembly order:
a. Remove the motor or remove the coupling.
b. Remove the bearing body assembly, check the radial clearance of the impeller and the front ring, check whether the impeller nut loose.
c. Remove the impeller nut, pull out the impeller, check the plug toe Bald Zhu 芊 饣 back to cut off the parsley 湎 Ding?
d. Loosen the tight seal of the mechanical seal and pull out the moving part of the mechanical seal. Check the fit of the moving and stationary end faces and check the seal of the O-ring [or cushion].
e. Unscrew the coupling adapter nut and pull out the coupling.
f. Remove the bearing cover and remove the shaft and bearings.
g. The installation can be done in reverse order.
3. Self-priming pump failure: pump out
cause:
1. There is no fluid in the pump housing or insufficient fluid
2. Inhalation pipe leakage
3 speed is too low
4. Suction too high or too long suction pipe
5. Mechanical seal leakage is too large
6. Suction pipe gas can not be discharged from the outlet
Method of exclusion:
1. Add enough stock solution
2. Check and correct the leak
3. Adjust the speed
4. Reduce suction or shorten suction line
Repair or replace
6. Exhaust it
Fault: noise and vibration larger
cause:
1. Feet unstable
2. The pump shaft is bent
Cavitation phenomenon
4. Bearing wear serious
5. There are debris imported pipe
6. Both pump and motor spindle is not concentric
Method of exclusion:
1. Reinforced
Replace or correct
3. Adjust the working conditions
4. Replacement
5 drops of debris
6. Adjust the coaxiality
Fault: lack of water
cause:
1. The impeller runner and suction tube are blocked
2. impeller or impeller seal wear and tear
3. Insufficient power or too low speed
Method of exclusion:
1. Remove the blockage
2. Change the mouth ring
3. Add enough power, adjusted to rated speed
Fault: shaft power consumption is too large
cause:
1. Flow too large
Speed ​​is too high
3. Pump shaft bending or impeller card touch
4. The pump runner is blocked or stuck
Method of exclusion:
1. Raise the outlet pressure
2. Appropriate to reduce
3. Replace or correct
4. Exclusion blockage