120bar/12MPa High Pressure Electric Cleaner, Water Cleaning Machine

Model NO.: E12-38
Certification: CE, CB, CSA, ETL, RoHS, UL, UR
Customized: Customized
Trademark: MEGAJET
Transport Package: Wooden Case
Specification: Standard
Origin: Beijing, China
HS Code: 8424300000
Model NO.: E12-38
Certification: CE, CB, CSA, ETL, RoHS, UL, UR
Customized: Customized
Trademark: MEGAJET
Transport Package: Wooden Case
Specification: Standard
Origin: Beijing, China
HS Code: 8424300000
Electric High Pressure Water Cleaner

Typical Applications:

Surface prep & cleaning
Pipeline cleaning
Chimney cleaning
Cooling tower cleaning
Fuel tank cleaning
Equipment maintenance
Floor cleaning
Car painting & grating cleaning
Vessel cleaning
Undersea device cleaning
Drying oven cleaning
Fluid statics test
Water jetting cutting

120bar/12MPa High Pressure Electric Cleaner, Water Cleaning Machine
120bar/12MPa High Pressure Electric Cleaner, Water Cleaning Machine

Features:

High strength, anti-corrosion high pressure pump with patent design
High accuracy inlet filtration system
Mechanical liquid-filling pressure gauge, showing pressure fluctuation of pump timely
Accurate pressure adjustable system
Auto-OFF intelligent control while gun stops working

120bar/12MPa High Pressure Electric Cleaner, Water Cleaning Machine

Specifications:
 
Model/Item E12-38 E25-18 E15-58 E35-23 E50-18 E50-22 E50-42 E60-30
Flow  L/min 38 18 58 23 18 22 42 30
Pressure  bar/Mpa 120/12 250/25 150/15 350/35 500/50 500/50 500/50 300/30
Max. Water Temperature ºC 60
Power   Kw 9 9 18.5 18.5 18.5 22 45 37
Power Supply  p/hz/v Customized
Weight   Kg 126 126 185 185 185 190 460 460
Dimensions  mm 780x650x800 780x650x800 960x650x800 960x650x800 960x650x800 1358x635x925 1285x700x1090

120bar/12MPa High Pressure Electric Cleaner, Water Cleaning Machine


Attachments:


1. Spraying gun
2. High pressure soft tube
3. Kinds of nozzles for different applications
4. Rotating spraying head
5. Water blasting elements
6. Pipeline cleaning tube 

120bar/12MPa High Pressure Electric Cleaner, Water Cleaning Machine

120bar/12MPa High Pressure Electric Cleaner, Water Cleaning Machine
Electric High Pressure Water Cleaner

Typical Applications:

Surface prep & cleaning
Pipeline cleaning
Chimney cleaning
Cooling tower cleaning
Fuel tank cleaning
Equipment maintenance
Floor cleaning
Car painting & grating cleaning
Vessel cleaning
Undersea device cleaning
Drying oven cleaning
Fluid statics test
Water jetting cutting

120bar/12MPa High Pressure Electric Cleaner, Water Cleaning Machine
120bar/12MPa High Pressure Electric Cleaner, Water Cleaning Machine

Features:

High strength, anti-corrosion high pressure pump with patent design
High accuracy inlet filtration system
Mechanical liquid-filling pressure gauge, showing pressure fluctuation of pump timely
Accurate pressure adjustable system
Auto-OFF intelligent control while gun stops working

120bar/12MPa High Pressure Electric Cleaner, Water Cleaning Machine

Specifications:
 
Model/Item E12-38 E25-18 E15-58 E35-23 E50-18 E50-22 E50-42 E60-30
Flow  L/min 38 18 58 23 18 22 42 30
Pressure  bar/Mpa 120/12 250/25 150/15 350/35 500/50 500/50 500/50 300/30
Max. Water Temperature ºC 60
Power   Kw 9 9 18.5 18.5 18.5 22 45 37
Power Supply  p/hz/v Customized
Weight   Kg 126 126 185 185 185 190 460 460
Dimensions  mm 780x650x800 780x650x800 960x650x800 960x650x800 960x650x800 1358x635x925 1285x700x1090

120bar/12MPa High Pressure Electric Cleaner, Water Cleaning Machine


Attachments:


1. Spraying gun
2. High pressure soft tube
3. Kinds of nozzles for different applications
4. Rotating spraying head
5. Water blasting elements
6. Pipeline cleaning tube 

120bar/12MPa High Pressure Electric Cleaner, Water Cleaning Machine

120bar/12MPa High Pressure Electric Cleaner, Water Cleaning Machine

I. High & Low voltage cabinets installation of power plant

1. 10KV high voltage switch cabinet installation of power plant

2. 0.4KV low voltage switch cabinet installation of power plant

3. Installation of generator protection system, synchronization system, transformer protection, H.V. motor protection, circuit protection in a power plant.

II. Electrical configuration testing items of power plant

1. Vacuum circuit breaker insulation resistance measurement, each phase circuit resistance measurement and AC voltage withstand tests of 10KV H.V. switch cabinet.

2. DC resistance measurement of CT and PT, polarity test, ratio test, AC voltage withstand tests in 10KV H.V. switch cabinet.

3. AC voltage withstand tests for whole 10KV H.V. switch cabinet.

4. AC resonant test for 10KV H.V. electric cable.

5. DC resistance measurement of generator stator and rotor.

6. Generator stator coil insulation resistance measurement and DC voltage withstand tests.

7. Generator rotor insulation resistance measurement.

8. Generator rotor AC impedance and power loss tests.

9. No-load characteristic test of generator

10. Generator checking phase sequence (fist checking phase and second checking phase separately).

11. Generator short circuit characteristic test.

12. Measurement of residual voltage of stator after automatic magnetic blow-out and switch opening of generator.

13. Generator shaft voltage measurement.

14. Generator simulate synchronization.

15. All of the second circuit checking, measuring, switch tripping & closing tests, protection fixed value setting, protecting the STG trip test and magnetic blow-out tripping test for Steam Turbine and generator.

III.Electrical problem troubleshooting in power plant

Problem Description: a coal mine`s 35KV H.T. switchgear OC protection tripped suddenly in He`nan Province, it caused sudden power lost of mine fan and endanger miner safety.

Auto-reclosing via switchgears` automatic reclosing function, through analysis, the reason is a set of 3000KW generator failure. Specific reason is: When the turbo-generator was running normally, exciting voltage lost suddenly, leading phase operation happened, the generator absorbed reactive power and lead to becoming motor running. Generator protection and power plant connecting line protection did not launch. After the generator absorbed a certain value of reactive power, the 35KV H.T. switchgear`s OC protection tripped.


Investigation: generator and power plant connecting line protection setting fixed value exceed the protection fixed value of 35KV switchgear side, it lead to nearby protection did not launch and override trip when generator failure.

Electrical Cabinet Care

Electrical Cabinet Care,10Kv Electrical Cabinet Care,0.4Kv Electrical Cabinet Care,Electric Governing Reconstructing

Shandong Qingneng Power Co., Ltd. , https://www.steamturbine.be