Intelligent integrated switch electric actuator installation

Intelligent integrated switch-type electric actuator comes with a control box, the so-called mechatronics. With liquid crystal display, can feedback 4 ~ 20mA standard signal, you can determine the valve's full open, fully closed, and the uncertain middle position, that is, switch control. Widely used in metallurgy, petroleum, chemical, water treatment and sewage treatment industries, applicable to butterfly valves, ball valves, plug valves, etc., as 90-degree rotary valves and similar equipment.

The intelligent integrated switch-type electric actuator is mounted on a reversible plate to adjust the torque control mechanism, stroke control mechanism, and opening degree indication mechanism. Intelligent integrated switch electric actuator button box has three buttons, the middle of the field and remote conversion button, the left side of the scene to close the valve button, the right is the scene to open the valve button, cover the button box for the remote control, remote DC 24V switch Contact control, open button box for on-site operation.

Installation of intelligent integrated switch-type electric actuators:

1. The bolts connecting the intelligent integrated switch electric actuator and the valve shall not be lower than 8.8.

2. When it needs to be disassembled, the manual handwheel should be rotated several times first, with the valve slightly open.

3. When the valve is not used frequently, it should be regularly checked and maintained and operated. The running time should not exceed 10 minutes.

4. When the intelligent integrated switch electric actuator is installed, the space required by the maintenance inspector to disassemble the components is ensured.

5. The intelligent integrated switch-type electric actuator device is a short-time working system, and the continuous working time shall not exceed the time specified on the nameplate.

6. When installing, disassembling and debugging, do not damage the sealing surface, seals and the explosion-proof surface of the explosion-proof electrical equipment. Apply anti-rust oil on the flameproof surface. The electrical cover should be tightly fastened to prevent rain or moisture. enter.

7. The installation form of the intelligent integrated switch-type electric actuator device has no principle requirements, but the motor is in the horizontal state, and the electric box cover is in the horizontal or vertical upward state as the recommended installation form, which is conducive to debugging, lubrication, maintenance and manual operation.

Holter ECG Monitoring System

Introduction

Holter ECG Monitoring Systems adopt 12-lead system of international standard, which can continuously record ECG waveform for 24-hour and analyze ECG waveform by the PC software. It is applicable for use in medical institution and community.


Analysis Software Function

1.The rate of checking RR wave up to 99.9%, which increased the accuracy of analysis without losing wave.

2.AI histogram function which can directly distinguish various abnormal ECG which can analyze faster.

3. Dynamic ECG [Channel Correct" function, which can correct mistakenly wearing that makes the analysis more accurate.

4.Lorenz and Demix analysis function, which can analyze more faster, more accurately. Single medical case can be completely analyzed in 10 min, which can reduce the physician`s work.

5.ST can be displayed in many kinds of form, which ensures that analyzing ST- Trends Diagram comprehensively, observing the whole or partial ST variety to analyze the specific area of myocardial ischemia.

6.Atrial fibrillation function can be recognized automatically and can distinguish atrial fibrillation case, give advice and generate analysis report .

7.Unique Cardiac Fatigue Index function, which can judge index of Cardiac Fatigue .High-risk groups can be found and early intervention treatment can be taken by the index, which can effectively judge the heart age and predict SCD (Sudden Cardiac Death).

8. P-wave analysis function, which can check cardiac arrhythmia (such as AVB).

9.According to the requirement of patients, options can be selected freely while printing report, which can save physician `s time

10. ECG can be printed by various forms according to the user`s requirement.

11.Pacemaker analysis function, which can analyze different pacemakers(such as AAI,VVI,DDD).

12.The comprehensive analysis system of stand-alone version with network version ,users can freely select any model.

13.Wire and wireless simultaneously transfer mode ,which reduce complicated performance.

14. Dynamic ECG and static ECG analysis system ,which reduced complex operations.

15. Time Domain and Frequency Domain function on HRV module can reflect the moderation effect of sympathetic and parasympathetic to the heart rate.

16.HRT function can predict myocardial infarction which has clinical value.

17.ST function which can check the exact time and length of myocardial ischemia in 24 hours.



Holter Monitor,Holter 24 Hours,Holter Recorder,Holter Ecg Monitoring System

Changchun Yingwang Times Digital Co., Ltd. , https://www.ccsdsm.com